The Association of Central corneal thickness with Intra- ocular Pressure of human being in AL Sadder Medical city
DOI:
https://doi.org/10.61841/cetw0j30Keywords:
Intra- ocular Pressure, Central corneal thickness, Corrected factors, Goldmann applanation tonometeryAbstract
Between intraocular pressure and central corneal thickness of 200 eye of 100 subjects consisting of males (n=53) (53%), and females (n=47) (47%) within ( 18-75) years with, mean age of (47.6±12.961) years. For all the subjects, mean corrected IOP (18.44±6.4575) mmHg. Mean CCT (524.775±41.796) μm. Mean corrected IOP for males (18.3113±6.48503) mmHg, and for females mean corrected IOP (18.5851±6.47123) mmHg. The CCT for males (525.5283±45.39594) μm and for females (523.92536±37.56521) μm. The study was shown that there is no liner relationship between IOP and CCT and the relation is inverse and not significant. It was also shown that neither CCT nor IOP was influenced by gender. And there was no difference between right and left eye. There was strong positive correlation between RT.CCT and LT.CCT. The slight association between CCT and age indicated a reduction of CCT with increasing age.
Downloads
References
1. Goldmann H, Schmidt T.U ber Applanationstonometrie. Ophthalmologica 1957;134:221– 42.
2. Ehlers N. On corneal thickness and intraocular pressure. II. A clinical study on the
thickness of the corneal stroma in glaucomatous eyes. Acta Ophthalmol (Copenh) 1970;48:1107–12.
3. Johnson M, Kass MA, Moses RA, Grodzki WJ. Increased corneal thickness
simulating elevated intraocular pressure. Arch Ophthalmol 1978;96:664 –5
4. Ehlers N, Bramsen T, Sperling S. Applanation tonometry and central corneal
thickness. Acta Ophthalmol (Copenh). 1975;53(1):34–43
5- Brandt J, Beisser J, Gordon M. Central corneal thickness in Ocular Hypertension treatment
study (OHTS). Ophthalmology. 2001;108(10):1779 88
6. Troost R, Vogel A, Beck S, Schwenn O, Grus F, Pfeiffer N. Comparison of two
Intraocular pressure measurement methods: Smartens® and goldmann’s tonometry. Graefes
Arch Clin Exp Ophthalmol 2001;239:889-892.
7. Kotecha A. Central corneal thickness and IOP: Novel measuring methods.
Instrument Insight 2005;22-23.
8. Grisson H, Smith ME, Netland PA. Current management of ocular hypertension.
Comp Ophthalmol update 2004;5(2):79-88.
9. Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular
pressure and central thickness. Ophthalmology 1998;105:1849-1854.
10. Phllips LT. Why Pachymetry? Review Optom 2003;48-52.
11. Whitacre MM, Stein R. Sources of error with use of Goldmann-type tonometers.
Surv Ophthalmol 1993;38:1-30. 115:592-596
12. Tonnu PA, Ho T, Elskeikh K, White E, Bunce C, garway-Heath D. The influence of
central corneal thickness and age on intraocular pressure measured by pneumotonometry,
non-contact tonometry, the Tono-pen XL and Goldmann applanation tonometry. Br J
Ophthalmol 2005;89:851-854.
13. Mederos FA, Sample PA, Weinret RN. Corneal thickness and frequency doubling
technology, perimetry abnormalities in ocular hypertensive eyes. Ophthalomology
2003;110:1903-1908.
14. Gordon MO, Beiser JA, Brandt JD, Heuer DK, Higginbothane EJ, Johnson CA,et al. The
Ocular Hypertension Treatment Study; Baseline factors that predict the onset of primary open-angle glaucoma. Arch ophthalmol 2002;120(96): 714-720.
15. Liu and Roberts, JCRS, JCRS 31, Issue 1, p 146-155 (January 2005)
16. Hansen FK, Ehlers N. Elevated tonometer readings caused by a thick cornea. Acta Ophthalmol. 1971;49:775–778.
17-Jack J Kanski and Brad bowling. Clinical ophthalmology a systemic approach. Seventh edition 2011.Elsevier.314-315
18-. Lleo A, Marcos A, Calafayud M, Alonso L, Rahhal SM, Sanchis-Gimeno JA. The
relationship between central corneal thickness and Goldmann applanation tonometry. Clin
Exp Optom 2003;86(2):104-108.
19. Herndon LW, Weizer JS, Stinnett SS. Central corneal thickness as a risk factor for
advanced glaucoma damage. Arch
Ophthalmol. 2004;122:17–21.
20. Ehlers N, Hansen FK, Aasved H. Biometric correlations of corneal thickness. Acta
Ophthalmol (Copenh).
1975;53:652–659.
21. Velten IM, Bergua A, Horn FK, Junemann A, Korth M. Central corneal thickness in
normal eyes, patients with ocular hyperten sion, normal-tension and open-angle glaucomas: a
clinical study (in German). Klin Monatsbl Augenheilkd. 2000;217:219–224
22-Bowman, W. Br Med J, 1852; 377-382
23-Schnabel I., Klin Montasbl Augenh 1908; 48:
24-. Bransem T, Ehlers N, Sperlings S. Applanation tonometry and central corneal thickness.
Acta ophthalmol1975;52:740-746.
25- Goldmann H, Schmidt T. Weiterer Beitrag zur Applanationstonometrie. Ophthalmologica
1961;141:441-456.
26- Munger R, Hodge WG, Mintsioulis G, Agapitos PJ, Jackson WB, Damji KF. Correction
of intraocular pressure for changes in central corneal thickness following photorefractive
keratectomy Can J Ophthalmol. 1998 Apr;33(3):159-65
27- Fournier AV, Podtetenev M, Lemire J, et al. Intraocular pressure change measured by
Goldmann tonometry after laser in situ keratomileusis. J Cataract Refract Surg.
1998;24:905–910.
28- Gimeno JA, Munoz LA, Valenzuela LA, Molto FJ, Rahhal MS. Influence of refraction
on tonometric readings after photorefractive keratectomy and laser assisted in situ
keratomileusis. Cornea. 2000;19:512–516
29- Orssengo GJ, Pye DC. Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo. Bull Mathematical Biol 1999;61:551-72.
30- Carolyn Y. Shih, MD; Joshua S. Graff Zivin, PhD; Stephen L. Trokel, MD; James C. Tsai,
MD - Clinical Significance of Central Corneal Thickness in the Management of Glaucoma Arch Ophthalmol. 2004;122:1270-1275
31. Bhan A, Browning AC, Shah S, Hamilton R, Dave D, Dua HS. Effect of corneal
thickness on intraocular pressure measurements with the pneumotonometer, Goldmann
applanation tonometer, and Tono- pen. Invest Ophthalmol Vis Sci 2002;43:1389-1392.
32. Stodtmeisser R. Applanation tonometry and correction according to corneal thickness.
Acta Ophthalmol Scand 1998;76:319-324.
33. Kaufmann C, Thiel MA, Seiler T. Pressure measurements after Laser in situ
keratomileusis: A comparison between Goldmann applanation tonometry and Dynamic
contour tonometry. SOG Switzerland 2002.
34. Nemesure B, Wu SY, Hennis A et al. Corneal thickness and intraocular pressure in
the Barbados Eye studies. Arch Ophthalmol 2003;1211:240-244.
35. Duch S, Serra A, Castanera J, Abos R, Quintana M. Tonometry after laser in situ keratomileusis treatment. J Glaucoma 2001; 10: 261 265.
36. Hoffmann EM, Grus FH, Pfeiffer N. Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry. BMC Ophthalmol 2004;4:4.
37. Fraser S, Manvikar S. Glaucoma: The pathophysiology of and diagnosis. Hosp Pharmacist 2005;12:251-254.
38. Valiki R, Choudhri SA, Tauber S, Shields MBJ. Effect of mild to moderate myopic correction by laser assisted keratomileusis on the intraocular pressure measurements with Goldmann applanationtonometer, Tono-pen and pneumotonometer. Glaucoma 2001;11:493-496.
Downloads
Published
Issue
Section
License
You are free to:
- Share — copy and redistribute the material in any medium or format for any purpose, even commercially.
- Adapt — remix, transform, and build upon the material for any purpose, even commercially.
- The licensor cannot revoke these freedoms as long as you follow the license terms.
Under the following terms:
- Attribution — You must give appropriate credit , provide a link to the license, and indicate if changes were made . You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
- No additional restrictions — You may not apply legal terms or technological measures that legally restrict others from doing anything the license permits.
Notices:
You do not have to comply with the license for elements of the material in the public domain or where your use is permitted by an applicable exception or limitation .
No warranties are given. The license may not give you all of the permissions necessary for your intended use. For example, other rights such as publicity, privacy, or moral rights may limit how you use the material.