Inter-rater Consistency Reliability of the Inertial Measurement Units as a Balance Evaluation Tool

Authors

  • Jeong-hee Jang M.D. Student, Dept. of Physical Therapy, Eulji University Author
  • Myung-chul Kim Professor, Dept. of Physical Therapy, Eulji University Author
  • Hang-sik Park Professor, Faculty of liberal art, Eulji University Author
  • Hae-in Kim Ph.D. Student, Dept. of Physical Therapy, Eulji University Author
  • Jean-kyung Paik Professor, Dept. of Food & Nutrition, Eulji University Author

DOI:

https://doi.org/10.61841/4bhstb83

Keywords:

Static Standing Balance, Trunk Shaking, IMUs(Inertial Measurement Units), Reliability, COG(Center Of Gravity)

Abstract

Background/Objectives: This study aim to evaluate the inter-rater consistency of static standing balance measurement equipment using inertial measurement system. Methods/Statistical analysis: 45 residents over 50 years old of Seongnam-si were recruited. The participants were randomly divided into 2 groups, and their static standing balance ability was measured by 2 physical therapists for 2 days. The measurements were performed on standing with open eyes, with closed eyes, standing on an unstable surface. The measured items were 3 parts, right and left trunk shaking, anterior and posterior trunk shaking, trunk rotation. Findings: For the open eyes part of the test, right and left trunk shaking’s Cronbach alpha was .552, and anterior and posterior trunk shaking’s Cronbach alpha was .626. And for the closed eyes part of the test, right and left trunk shaking’s Cronbach alpha was .409 and anterior and posterior trunk shaking’s Cronbach alpha was .623. Finally, for the unstable surface part of the test, only anterior and posterior trunk shaking data was able to be checked and the result was .570. The trunk rotation of all standing posture didn’t give significant Cronbach alpha data. Reliability of anterior and posterior trunk shaking in the all position was confirmed. And the right and left trunk shaking showed that there is reliability in the partly position. And there is no reliability in the trunk rotation of all standing position. Improvements/Applications: The results of this study shows the IMUs as a balance evaluation tool has moderate reliability in partial items.

Downloads

Download data is not yet available.

References

[1] Shumway-cook A, Woollacott MH. Motor control: translating research into clinical practice. Lippincott William & Wilkins; c2007. p. 287-288.

[2] Horak FB, Wrisley DM, Frank J. The Balance Evaluation Systems test (BESTest) to differentiate balance deficits. Phys Ther. 2009 May;89(5):484-98. DOI: 10.2522/ptj.20080071

[3] Gill J, Allum JH, Carpenter MG, Held-Ziolkowska M, Adkin AL, Honegger F, et al. Trunk sway measures of postural stability during clinical balance tests: effects of age. J Gerontol A Biol Sci Med Sci. 2001 Jan;56(7):M438-47. DOI: 10.1093/gerona/56.7.m438

[4] Kwon OY, Choi HS. Evaluation of the Balance Ability for 20 to 29 years Old on the Unstable Platform. Korean Research Society of Physical Therapy. 1996 Nov;3(3):1-11. Available from: http://www.koreascience.or.kr/article/JAKO199616549671911.page (website)

[5] Han SK, Lee SY, Lee DH, Park JS. Validity Study of Dynamic Balance Ability Measure using a Smartphone. J Korean Soc Phys Med. 2016 Apr;11(2):77-82. DOI: 10.13066/kspm.2016.11.2.77.

[6] Kim JH, Choi BR. Intra- and Inter-rater Reliability of BioRescue. The Journal of the Korea Contents Association. 2018 Nov;18(11):348-52. DOI: 10.5392/JKCA.2018.18.11.348

[7] Soon KS, Lee MY, Tsai WW, Lin CF. A new trunk sway assessment protocol using biofeedback inertial- based sensing modality for stroke patients. Institute of Electrical and Electronics Engineers. 2011 Jun. DOI: 10.1109/ICSSE.2011.5961988

[8] Winter DA. Human balance and posture control during standing and walking. Gait & Posture. 1995 Dec;3(4):193-214. DOI: 10.1016/0966-6362(96)82849-9

[9] Klaus S. The fourth industrial revolution. Geneva:World economic forum; 2016. p. 25.

[10] Ligorio G, Sabatini AM. A Novel Kalman Filter for Human Motion Tracking With an Inertial-Based Dynamic Inclinometer. IEEE Trans Biomed Eng. 2015 Mar;62(8):2033-44. DOI: 10.1109/TBME.2015.2411431

[11] Shin JD, Youm CH, Moon DS, Kim WK, Park YH. Analysis of proper sampling duration in foot positions during assessment of quiet stance balance in the elderly women using center of pressure. Korean journal of sports biomechanics. 2008 Sep;18(3):23-31. DOI: 10.5103/KJSB.2008.08.3.023

Downloads

Published

30.09.2020

How to Cite

Jang, J.- hee, Kim, M.- chul, Park, H.- sik, Kim, H.- in, & Paik, J.- kyung. (2020). Inter-rater Consistency Reliability of the Inertial Measurement Units as a Balance Evaluation Tool. International Journal of Psychosocial Rehabilitation, 24(7), 1780-1787. https://doi.org/10.61841/4bhstb83