Professor, Department of Nursing, Daewon University College, 316, Daehak-ro, Jecheon, 27135, Korea
DOI:
https://doi.org/10.61841/1hg9a281Keywords:
Pediatric, Chest X-ray, Breast X- ray, Shield, Apron, RadiationAbstract
Background/Objectives: This study was important to reduce genital radiation exposure during pediatric chest and breast X-ray, evaluate ease of a newly developed shielded apron, and helped parents and assistants monitor patient’s movements.
Methods/Statistical analysis: If there are a various factors, such as pediatric patients, difficulty to accurately position due to the movement of the patient. To solve such problems, examinations are often conducted with the assistance of parents and helpers who control a patient’s movements during pediatric chest and breast X-ray examination. During the process, parents and helpers are unnecessarily exposed to radiation even though they wear aprons.
Findings: This syudy, a newly developed shield was developed to prevent unnecessary radiation exposure by comparing the radiation dose associated with the use of gonad shield aprons in chest and breast X-ray of pediatrics patients. In this study, we use a newly developed shielding apron to shield the genitals during chest and breast X-ray and to reduce unnecessary radiation exposure to parents and helpers who control a patient’s movements during examinations.
Improvements/Applications: Using a newly developed shield apron at chest and breast X-rays reduces genital radiation exposure and unnecessary radiation dosage for parents and helpers controlling pediatric patients movement.
Downloads
References
1. Kim YH, Choi JH, Kim Jm, Kim JM, Kim SS, Oh YW, et al. Patient dose measurements in diagnostic radiology in Korea. Radiat. Prot. Dosimetry. 2007;123(4):540-5.
DOI:10.1093/rpd/ncl501.
2. International Commission on Radiological Protection. Radiological protection in paediatric diagnostic and interventional radiology. ICRP publication 121:Elsevier Press; 2013.
3. International Atomic Energy Agency, International basics safety standards for protection against ionizing radiation and the safety of radiation sources. Safety Series 115(Vienna: IAEA); 1996. p. 278-80.
4. Orito T. Investigation of accrual situation of radiological techniques to take measures for patient exposure dose reduction. Jpn. J. Rad iol. Technol. 1974;32: 34-9.
5. Suzuki S, Orito T, Koga S. Changes in X-ray diagnostic technology and patient exposure dose comparison with 1973 and 1979. J. Med. Imaging Inf. 1990;22(6): 359-63.
6. National Radiological Protection Board. National protocol for patient dose measurements in diagnostic radiology. Institute of Physical Science in Medicine (Chilton, Didcot: NRPB); 1992.
7. Cho PK, Seo BK, Choi TK, Kim JS, Kim YH, Choi JH, et al. The development of a diagnostic reference level on patient dose for CT examination in Korea. Radiat. Prot. Dosim. 2008;129(4): 463-8. DOI:10.1093/rpd/ncm463.
8. Choi JH, Cha SH, Lee KY, Shin DC, Kang JH, Kim YH, et al. The development of a guidance level for patient dose for CT examinations in Korea. Radiat. Prot. Dosim. 2010;138(2): 137-143.
DOI:10.1093/rpd/ncp236
9. International Commission on Radiological Protection. 1990 Recommendation of the international commission on radiological protection. ICRP publication 60. Annals of the ICRP 21(1-3): Elsevier Press; 1991.
10. International Commission on Radiological Protection. Radiological protection and safety in medicine. ICRP publication 73. Annals of the ICRP 26(2): Elsevier Press; 1996.
11. International Commission on Radiological Protection. Protection of the patient in diagnostic radiology. ICRP publication 34. Annals of the ICRP 9(2): Elsevier Press; 1983.
12. Council Directive 97/43/EURATOM of 30 Jun 1997 on health protection of individuals against the dangers of ionizing radiation in relation to medical exposure; 1997. p. 22.
13. European Commission. European guidelines on quality criteria for diagnostic radiographic images. CEC-Report EUR 16260. Luxembourg: Office for Official Publications of the European Communities; 1996.
14. European Commission. European guidelines on quality criteria for diagnostic radiographic images in pediatrics. CEC- Report EUR 16261. Luxembourg: Office for Official Publications of the European Communities; 1996.
15. European Commission. European guidelines on quality criteria for computed tomography. CEC-Report EUR 16262. Luxembourg: Office for Official Publications of the European Communities; 1999.
16. Cho PK. The development of a diagnostic reference level on patient dose for head computed tomography angiography examinations in Korea. Radiat. Prot. Dosim. 2013;154(4): 505-9.
DOI:10.1093/rpd/ncs264
17. Korea Food and Drug Administration. Exposure parameters for pediatric radiography in Korea. Radiation Safety Series 22; 2010.
18. Korea Food and Drug Administration. The Diagnostic Reference Level for pediatric CT examinations in Korea. Radiation Safety Series 31; 2012.
19. Korea Food and Drug Administration. The Diagnostic Reference Level for pediatric general X-ray examinations in Korea. Radiation Safety Series 34; 2013.
20. Korea Food and Drug Administration. The guideline for pediatric general X-ray examinations in Korea. Radiation Safety Series 35; 2013.
21. Wrixon AD. New ICRP recommendations. J Radiol Prot. 2008;28:161-8. DOI:10.1088/0952-4746/28/2/R02
22. Fawcett SL, Barter SJ. The use of gonad shielding in pediatric hip and pelvis radiographs. The Brit J Radiol. 2009;82: 363-70. DOI:10.1259/bjr/86609718
23. Hodges PC, Strandjord NM, McCrea A. A testicular shield. J Am Med Assoc. 1958;167: 1239-1240.
24. Brindhaban A, Al-Khalifah K. Radiation dose to premature infants in neonatal intensive care units in Kuwait. Radiat Prot Dosimetry. 2004;111(3): 275-81. DOI:10.1093/rpd/nch338
25. Makri T, Yakoumakis E, Papadopoulou D, Gialousis G, Theodoropoulos V, Sandilos P, Georqiou E. Radiation risk
assessment in neonatal radiographic examinations of the chest and abdomen: a clinical and Monte Carlo dosimetry study. Phys Med Biol. 2006;51(19): 5023-33.
DOI:10.1088/0031-9155/51/19/019
26. Sikand M, Stinchcombe S, Livesley PJ. Study on the use of gonadal protection shields during paediatric pelvic X- rays. Ann Roy Coll Surg. 2003;85(6): 422-5.
DOI: 10.1308/003588403322520852
27. Willis CE, Slovis TL. The ALARA concept in radiographic dose reduction. Radiol Technol. 2004;76(2): 150-2. https://www.ncbi.nlm.nih.gov/pubmed/15587617
28. Willis CE, Slovis TL. The ALARA concept in pediatric CR and DR: dose reduction in pediatric radiographic exams a white paper conference executive summary. Pediatr Radiol. 2004;34(3): 162-4. DOI:10.1007/s00247-004-1264-y
29. Don S, Goske MJ, John S et al. Image Gently pediatric digital radiography summit: executive summary. Pediatr Radiol. 2011;41(5): 562-5. DOI:10.1007/s00247-010-1966-2
Published
Issue
Section
License

This work is licensed under a Creative Commons Attribution 4.0 International License.
You are free to:
- Share — copy and redistribute the material in any medium or format for any purpose, even commercially.
- Adapt — remix, transform, and build upon the material for any purpose, even commercially.
- The licensor cannot revoke these freedoms as long as you follow the license terms.
Under the following terms:
- Attribution — You must give appropriate credit , provide a link to the license, and indicate if changes were made . You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
- No additional restrictions — You may not apply legal terms or technological measures that legally restrict others from doing anything the license permits.
Notices:
You do not have to comply with the license for elements of the material in the public domain or where your use is permitted by an applicable exception or limitation .
No warranties are given. The license may not give you all of the permissions necessary for your intended use. For example, other rights such as publicity, privacy, or moral rights may limit how you use the material.